Net data (PKW and PZD area)
5-235
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-16
Status word ZSW2
ZSW
2
Suppress fault 608 active (from SW 3.1)
Actual motor 1st signal (from SW 2.4)
1)
Actual motor 1st signal (from SW 2.4)
1)
Slave sign–of–life
(from SW 3.1)
Motor being changed over (from SW 3.3)
1)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Parking axis selected
Integrator inhibit, speed controller
Open holding brake
Ramp–function gen. inactive
First speed setpoint filter inactive
Bit 2
Bit 1
Bit 0
Parameter set
Note:
From the perspective of SIMODRIVE 611 universal, status signals are output signals and are described
in Chapter 6.4.6.
Also refer in the index under ”Output signal, digital ...”).
1) Only available in the n–set mode
For closed–loop speed controlled operation, the speed actual value is
displayed as follows:
NIST_A (nist–h)
––> lower resolution
NIST_B (nist–(h+l))
––> higher resolution
nist–l
ZSW
1
ZSW
2
NIST_B
NIST_A
nist–h
Note
The speed actual value is signaled in the same format as the speed
setpoint is specified
(refer to control word NSOLL_A (nsoll–h) and NSOLL_B (nsoll–(h+l)).
Status word ZSW2
Status word
NIST_A
NIST_B
5 Communications via PROFIBUS DP