2
2.1
Installing/removing control boards and modules
2-61
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
An option module is installed/removed from the control board as follows
(refer to Fig. 2-1):
!
Warning
When installing/removing an option module, observe the ESDS
measures.
1. Ensure that the control board is in a no–voltage condition.
2. Removing (changing):
Release the screws at the slot and withdraw the option module
from the ”old” control board.
Installing:
Remove the screws for the cover at the slot for the option module.
3. Insert the module through the front panel until it latches into place.
4. Tighten up the screws holding the module
(2 screws in the front panel, max. torque = 0.8 Nm).
5. Connect–up the front panel of the option module corresponding to
the connection diagram (refer to Chapter 2.3.3).
The mating connectors are inserted at the appropriate interface.
Power module
”SIMODRIVE 611 universal”
control board
Optional TERMINAL module
or
Optional PROFIBUS–DP
module
...
Screw
Screw
Screw
For screws:
Tighten (due to the shield contact)
Max. torque = 0.8 Nm
Mounting
slot for
Memory module
Screw
SIMODRIVE
SIEMENS
Fig. 2-1
Installing the control board and an option module
Note
The PROFIBUS firmware, associated with the 611u firmware must be
available on the PROFIBUS–DP option module. Otherwise the
firmware must be upgraded. PROFIBUS–DP1 option modules from
SW 4.1 – and also in this particular case – can no longer be used.
Installing/
removing an
option module
2 Installing and Connecting-Up
01.99
08.02