3
3.3
Parameterizing using the parameterizing and start–up tool SimoCom U
3-109
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
3.3.4
Online operation: SimoCom U via PROFIBUS–DP (from SW 3.1)
The ”SimoCom U” parameterizing and start–up tool can communicate
with the drives via the serial interfaces and also via the PROFIBUS–DP
fieldbus.
The following online modes are possible:
Online operation via the CP 5511/CP 5611/CP 5613 directly with the
fieldbus
PC/PG <––> CP 5511 / CP 5611 / CP 5613 <––> PROFIBUS <––>
drives
Online operation via the MPI interface of SIMATIC S7
PC/PG <––> MPI <––> PROFIBUS <––> drives
If the subsequently listed prerequisites are fulfilled, then online oper-
ation can be established between SimoCom U, and all of the drives
connected to the bus (”DP slaves 611U”).
For SimoCom U, communications via PROFIBUS–DP can be set as
follows:
Options – Settings – Communications ––> ”Interface” dialog”
For ”For ”Go online” connect via” set the following:
––>
”PROFIBUS” and
––> ”Direct
connection”
––> if the coupling is directly with the field bus
or
––>
”MPI –> PROFIBUS Routing”
––> if the coupling is via the MPI interface
or
––>
”Communication via OPC server” (from SW 6.1)
––> if the coupling is via OPC server
Then, online operation can be established directly to the drive via the
fieldbus using the ”Search for online drives” function.
Description
Settings for
SimoCom U
3 Parameterizing the Board
01.99
06.04