5
5.6
Net data (PKW and PZD area)
5-233
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
5.6.3
Description of the status words (actual values)
Table 5-14
Status word ZSW1 for the n–set mode
Spindle positioning on (from SW 5.1)
Open–loop torque controlled mode
Comparison value reached/comparison value not reached
Control requested/no control possible
n
set
= n
act
ZSW
1
n–
ist–
h
n–
ist–
l
ZSW
2
Reserved
Function generator active (from SW 6.1)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Warning present/no warning present
Power–on inhibit/no power–on inhibit
No OFF 3 present/OFF 3 present
No OFF 2 present/OFF 2 present
Fault present/no fault present
Status, controller enable
Ready or no fault
Ready to be powered–up/not ready to be powered–up
Note:
From the perspective of SIMODRIVE 611 universal, status signals are output signals and are described
in Chapter 6.4.6.
Also refer in the index under ”Output signal, digital ...”).
Status word ZSW1
(n–set mode)
5 Communications via PROFIBUS DP
08.99
08.02