6.10 Parameter set changeover
6-578
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-59
Parameter set–dependent parameters, continued
Parameters for parameter set
Operating
mode
0
Description
pos
n
set
7
...
1
1417:0
1417:1
...
1417:7
x
x
n_x for ”n_act < n_x” signal
1418:0
1418:1
...
1418:7
x
x
n_min for ”n_act < n_min” signal
1421:0
1421:1
...
1421:7
x
x
Time constant, integrator feedback (speed controller)
1426:0
1426:1
...
1426:7
x
x
Tolerance bandwidth for ”n_set = n_act” signal
1428:0
1428:1
...
1428:7
x
x
Threshold torque M_x (ARM, SRM)
Threshold force F_x (SLM)
1451:0
1451:1
...
1451:7
x
x
P gain, speed controller IM (ARM)
1453:0
1453:1
...
1453:7
x
x
Integral action time, speed controller IM (ARM)
1500:0
1500:1
...
1500:7
Speed setpoint filter (ARM, SRM)
to
to
to
x
x
Speed setpoint filter (ARM, SRM)
Velocity setpoint filter (SLM)
1521:0
1521:1
...
1521:7
Velocity setpoint filter (SLM)
Note:
x:
The parameter is available in this operating mode
–:
The parameter is not available in this operating mode
x
1)
for spindle positioning (from SW 5.1)
Note
Only parameter set 0 is parameterized using this SimoCom U
parameterizing and start–up tool via the interactive dialog operation.
Parameter sets 1 to 7 must be parameterized using the Expert list of
SimoCom U.
You can toggle between parameter sets 0 and 7 using
the following input signals:
Input signal ”parameter set changeover 1st input”
Input signal ”parameter set changeover 2nd input”
Input signal ”parameter set changeover 3rd input”
How can you
toggle between
parameter sets?