1
1.4
”SIMODRIVE 611 universal E” control board
1-47
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 1-5
Overview of the board–specific terminals and interfaces, continued
Terminals
Technical data
Type
1)
Function
No.
Technical data
Type
1)
Function
Desig-
nation
663
X431.4
Pulse enable
(+24 V)
I
Voltage tolerance
(including ripple):
21 V to 30 V
Typ. current consumption:
25 mA at 24 V
Note:
The pulse enable acts simultaneously on drive A and
drive B. When this pulse enable is withdrawn, the
drives ”coast down” unbraked.
19
X431.5
Reference
(Reference for all
digital inputs)
S
Note:
If the enable signals are to be controlled from an exter-
nal voltage and not from terminal 9, then the reference
potential (ground) of the external source must be con-
nected to this terminal.
Serial interface (X471)
–
X471
Serial interface for
”SimoCom U”
IO
Connector type: 9–pin D–sub socket connector
Note:
The interface can only be used as RS232 interface
––> refer to Chapter 3.3.3
Pin assignment of the interface ––> refer to Chap-
ter 2.4
Cable diagram for RS232 ––> refer to Chapter 2.5
PROFIBUS–DP interface (X423) for the optional PROFIBUS–DP3 module
–
X423
Communications in-
terface for
PROFIBUS
IO
Connector type: 9–pin D–sub socket connector
Note:
Pin assignment of the interface ––> refer to Chap-
ter 2.4
Connecting diagram and connecting–up the op-
tional PROFIBUS–DP module ––> refer to Chapter
2.3.4
Communications via PROFIBUS–DP
––> refer to Chapter 5
Equipment bus (X351)
–
X351
Equipment bus
IO
Ribbon cable:
34–pole
Voltages:
various
Signals:
various
Test sockets (X34)
DAU1
Test socket 1
2)
MA
Test socket:
∅
2 mm
Resolution:
8 bit
DAU2
X34
Test socket 2
2)
MA
Resolution:
8 bit
Voltage range:
0 V to 5 V
M
Reference
MA
Voltage range:
0 V to 5 V
Maximum current:
3 mA
1) I: Input; S: Supply; IO: Input/output; MA: Measuring signal, analog