Parameter list
A-846
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1717
Limiting factor for torque/power (ARM SRM)
Limiting factor for force/power (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
%
Floating Point
RO
... displays the actual limiting factor for torque/power or force/power (SLM).
Note:
refer to the index entry ”Torque/power reduction”
1718
Torque-generating current Iq (A)
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
A(rms)
Floating Point
RO
... displays the torque-generating current Iq as RMS value.
Note:
The display of the torque-generating current actual value is smoothed using a PT1 filter
(P1250).
1719
Actual absolute current (rms)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
A(rms)
Floating Point
RO
Displays the motor phase current RMS.
1723
Diagnosis, ramp-up time
Min
Standard
Max
Unit
Data type
Effective
–
–
–
ms
Unsigned16
RO
Note: Internal Siemens
1724
Diagnosis, rotational accuracy monitor
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
Note: Internal Siemens
1725
Normalization of torque setpoint (ARM SRM)
(–> 2.4)
Normalization of force setpoint (SLM)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
N
Floating Point
RO
(SLM)
–
–
–
Nm
Floating Point
RO
(SRM ARM)
... specifies the reference value for the status word Mset for PROFIBUS.
The following applies before SW 4.1: The value corresponds to 800% of the rated motor torque.
From SW 4.1 the following applies: The value corresponds to P0882 * rated motor torque.
1726
Calculated jerk time
(–> 3.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
ms
Floating Point
RO
... displays the calculated jerk time which is currently effective.
Note: refer to the index entry ”Jerk limitation”
1729
Actual rotor position (electrical)
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Degree
Floating Point
RO
...displays the actual electrical rotor position.