A
A.1
Parameter list
A-838
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1521:8
BSP natural frequency, speed setpoint filter 2 (ARM SRM)
BSP natural frequency, velocity setpoint filter 2 (SLM)
Min
Standard
Max
Unit
Data type
Effective
1.0
100.0
141.0
%
Floating Point
immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1522
Time constant, speed actual value filter (PT1) (ARM SRM)
Time constant, velocity actual value filter (PT1) (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
500.0
ms
Floating Point
immed.
Encoder with sin/cos 1 Vpp:
Default corresponding to the appropriate encoder
– Single absolute value encoder (EQI, 32 pulses/revolution): 1 ms
– Toothed-wheel encoder (SIZAG 2, 256/512 pulses/revolution): 1 ms
– Absolute value encoder for SRM
(shaft height 28/26, 512 pulses/revolution): 1 ms
– Absolute value encoder (EQN, 2048 pulses/revolution): 0 ms
– Incremental encoder (ERN, 2048 pulses/revolution): 0 ms
Note: refer to the index entry ”Encoder adaptation”
Resolver:
Default, 12 bit resolution
– ARM: 2 ms
– SRM/SLM: 0.8 ms
Default, 14 bit resolution
– ARM: 2 ms
– SRM/SLM: 0.2 ms
1600
Suppressible faults 1
Min
Standard
Max
Unit
Data type
Effective
0
0
7FFF
Hex
Unsigned16
immed.
The following faults can be suppressed using these bits.
Bit 4
measuring circuit, motor measuring system (fault 504)
Bit 5
monitoring absolute track (fault 505)
Bit 7
synchronizing error, rotor position (fault 507)
Bit 8
zero mark monitoring, motor measuring system (fault 508)
Bit 9
converter limiting frequency too high (fault 509)
Bit 12 Measuring circuit, direct measuring system (Fault 512)
Bit 13 Monitoring, absolute track, direct measuring system (fault 513)
Bit 14 Zero mark monitoring, direct measuring system (fault 514)
Note:
When suppressing the zero mark monitoring with P1600.8 or P1600.14, only faults 508 or 514
are suppressed; however, the internal monitoring functions still remain active.
Bit x = ”1” ––> Fault is suppressed, i.e. de-activated
Bit x = ”0” ––> Fault is activated