6
6.7
Analog outputs
6-548
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-56
Signal selection list for analog outputs, continued
Signal
Normaliza-
tion
(corre-
sponds
to LSB)
Units
Bit
width
Shift
fac-
tor
Displayed
in
Operating
mode
No.
Normaliza-
tion
(corre-
sponds
to LSB)
Units
Bit
width
Shift
fac-
tor
Displayed
in
pos
n–set
Designation
36
Torque setpoint (finely
normalized) (SRM, ARM)
Nm
Force setpoint (finely normal-
ized) (SLM)
Note: P0625 is the reference
x
x
–
0
24
N
P1742
37
Speed setpoint at terminals
56.x/14.x, 24.x/20.x (SRM,
ARM)
x
x
–
6
RPM
P1711
Velocity setpoint at terminals
56.x/14.x, 24.x/20.x (SLM)
x
x
–
6
m/min
P1711
38
Signal DAU1 from
PROFIBUS–PPO
x
x
–
0
16
–
–
39
Signal DAU2 from
PROFIBUS–PPO
x
x
–
0
16
–
–
40
Speed setpoint from
PROFIBUS PPO (SRM,
ARM)
x
x
–
6
24
RPM
P1711
Velocity setpoint from
PROFIBUS PPO (SLM)
x
x
–
6
24
m/min
P1711
41
Rotor position, finely/coarsely
synchronized (from SW 5.1)
0: Still not synchronized
1: Coarsely synchronized
3: Coarsely and finely syn-
chronized
x
x
–
21
16
–
–
42
Input terminals (refer to
P0678) (from SW 5.1)
x
x
–
7
16
–
–
43
Torque setpoint limit (neg.)
(SRM, ARM)
Force setpoint limit (neg.)
(SLM) (from SW 7.1)
x
x
–
4
24
Nm
N
P1713
44
Speed correction value
(SRM, ARM)
Velocity correction value
(SLM) (from SW 7.1)
x
x
–
0
24
RPM
m/min
P1711
45
to
69
Reserved
–
–
–
–
–
–
–
70
Position controller output
(SRM, ARM)
x
x
–
6
RPM
P1711
(SLM)
x
x
–
6
m/min
P1711
6 Description of the Functions
01.99
04.99
02.03