6
6.11 Motor changeover for induction motors (from SW 2.4)
6-583
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-61
Motor data set–dependent parameters, continued
Motor data set
Meaning
1
4
3
2
1400
2400
3400
4400
Rated motor speed
1401:8
2401:8
3401:8
4401:8
Speed for the max. useful motor speed
1403
2403
3403
4403
Shutdown speed, pulse cancellation
1405:8
2405:8
3405:8
4405:8
Monitoring speed, motor
1407:8
2407:8
3407:8
4407:8
P gain of speed controller
1408:8
2408:8
3408:8
4408:8
P gain, upper adaptation speed
1409:8
2409:8
3409:8
4409:8
Integral action time, speed controller
1410:8
2410:8
3410:8
4410:8
Integral action time, upper adaptation speed
1411
2411
3411
4411
Lower adaptation speed
1412
2412
3412
4412
Upper adaptation speed
1413
2413
3413
4413
Select adaptation, speed controller
1417:8
2417:8
3417:8
4417:8
nx for ”nact < nx” signal
1418:8
2418:8
3418:8
4418:8
nmin for ”nact < nmin” signal
1426:8
2426:8
3426:8
4426:8
Tolerance bandwidth for ”nset = nact” signal
1451:8
2451:8
3451:8
4451:8
P gain, speed controller IM
1453:8
2453:8
3453:8
4453:8
Integral action time, speed controller IM
1458
2458
3458
4458
Current setpoint, open–loop controlled range IM
1459
2459
3459
4459
Torque smoothing time constant IM
1465
2465
3465
4465
Changeover speed, MSD/IM
1466
2466
3466
4466
Changeover speed, closed–loop/open–loop control IM
1602
2602
3602
4602
Warning threshold, motor overtemperature
1607
2607
3607
4607
Shutdown limit, motor temperature
1608
2608
3608
4608
Fixed temperature
1712
1)
2712
1)
3712
1)
4712
1)
Weighting, rotor flux representation
1713
1)
2713
1)
3713
1)
4713
1)
Weighting, torque representation
1725
1)
2725
1)
3725
1)
4725
1)
Normalization, torque setpoint
1) These parameters are read–only.
6 Description of the Functions
01.99
04.99
! not 611ue !