A
A.1
Parameter list
A-732
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
A.1
Parameter list
Reader’s note
The parameters listed in the following are valid for all of the software
releases of ”SIMODRIVE 611 universal”.
The complete list is updated corresponding to the edition of this
documentation (refer to the edition in the header lines) and
corresponds here to the documented software releases of
”SIMODRIVE 611 universal”.
The parameters are designated depending on the particular software
release.
The parameters are listed as follows:
xxxx
word_word word_word word_word (yyy)
(–> x.y)
Min
Standard
Max
Units
Data type
Effective
(yyy)
xx
xx
xx
yy
zz
uu
Significance of the parameter numbers (examples)
(refer under the index entry ”Parameters – ...)
P1400
Parameter 1400 with sub–parameters
P1401:8
Parameter 1401 with 8 sub–parameters
P0081:64
Parameter 0081 with 64 sub–parameters
Parameter text
Valid for ... motors
none
all
SRM
rotating synchronous
ARM
rotating induction
SLM
synchronous linear
RO
(Read Only)
can only be read
immed.
is effective immediately when changed
PO
POWER ON
when changed, becomes effective after
POWER ON
PrgE
End of program is
effective if none of the programs
(block processing) are active
Vsoll_0
Velocity setpoint zero
Effective for a velocity setpoint = 0
Information on effective
In order that a parameter ”immediately” becomes
effective after a change, it may be necessary to
execute the associated function (e.g. P0160
(reference point coordinates) a reference point
approach must be carried out).
Parameter numbers
Motor dependency
Units
MSR: Dimension system grid
1 MSR = 0.001 mm
for P0100 = 1
1 MSR = 0.0001 inch
for P0100 = 2
1 MSR = 0.001 degrees for P0100 = 3
c * MSR
c = 1:
for a dimension system mm or
inch
c = 10: for a dimension system, degrees
Example:
P0082:64 = 50 000 [c*MSR/min]
Dimens. system Significance
––>
mm 50
mm/min
––>
inch
5 inch/min
––>
degrees
500 degrees/min
Software release
no data:
... available from SW 2.1
e.g.: –> 2.4 :
... available from SW 2.4
Fig. A-1
Parameter list
General
information on the
parameter list
A Lists
01.99
04.99