A
A.1
Parameter list
A-840
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1605
Timer n controller at stop
Min
Standard
Max
Unit
Data type
Effective
20.0
200.0
10000.0
ms
Floating Point
immed.
... specifies how long the speed controller or velocity controller output can be at its limit without
fault 608 being output.
Important:
If P1605 < P1404, then regenerative braking can be exited with fault 608, whereby the drive
then ”coasts down”.
Note: refer to the index entry ”Monitoring functions”
1606
Threshold n controller at stop
Min
Standard
Max
Unit
Data type
Effective
0.0
30.0
100000.0
rpm
Floating Point
immed. (ARM)
0.0
500.0
100000.0
m/min
Floating Point
immed. (SLM)
0.0
90000.0
100000.0
rpm
Floating Point
immed. (SRM)
... specifies up to which speed or velocity the torque setpoint or force setpoint monitoring is ac-
tive, i. e. up to this value, fault 608 can be output (speed controller at the endstop).
Note:
In the case of PE spindles (P1015=1), the standard assignment will be as with ARM (30.0
rpms).
refer under index entry ”Monitoring functions”
1607
Shutdown limit motor temperature
Min
Standard
Max
Unit
Data type
Effective
0
155
200
C
Unsigned16
immed.
... defines the shutdown limit for the motor temperature monitoring without pre-alarm.
When this temperature threshold is exceeded, the drive is shut down, the pulses canceled and
fault 613 output.
Note:
The monitoring function can be enabled/disabled via P1601.13.
The temperature monitoring functions with/without pre-alarm (P1602 + P1603 or P1607) are not
mutually restricted, i. e. P1607 < P1602 is permissible.
Refer under the index entry ”Monitoring functions”.
1608
Fixed temperature
Min
Standard
Max
Unit
Data type
Effective
0
0
200
C
Unsigned16
immed.
If a value > 0 is entered, then the rotor resistor is adapted, temperature-dependent, with this
fixed temperature.
Note:
The measured temperature is then no longer monitored and parameters 1602, 1603 and 1607
are then no longer effective.
A fixed temperature can, e. g. be required, if a motor does not have a temperature sensor.
Thus, e.g. the temperature monitoring of linear motors is disabled for the case where the moni-
toring is realized via an external PLC.
Refer under the index entry ”Monitoring functions”.
1610
Diagnostic functions
Min
Standard
Max
Unit
Data type
Effective
0
1
3
Hex
Unsigned16
PO
(ARM)
0
0
3
Hex
Unsigned16
PO
(SRM SLM)
Note: Internal Siemens
A Lists
01.99
! 611ue diff !
04.05