3
3.3
Parameterizing using the parameterizing and start–up tool SimoCom U
3-98
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
3.3.2
Entry into SimoCom U
The SimoCom U parameterizing and start–up tool is installed and star-
ted on the PG/PC acc. to Chapter 3.3.1.
The following basic screen is displayed after the first start:
Fig. 3-8
Basic screen of SimoCom U for the latest version
Note
When using SimoCom U, please be aware of the following:
The program attempts to ”think with you”:
If you select a command, which is presently not available for a
specific reason (e.g. you are offline and wish to ”move an axis ”),
then the program does what you would probably wish it to do:
It goes ”online”, and offers you a list of drives and after the required
drive has been selected, it opens the traversing window. However,
if you do not wish to do this, then you can exit and continue as
required.
Only the information is provided in the dialog boxes which must be
available as a result of the selected configuration.
Example:
If a synchronous motor is set, then a ramp–function generator is
not made available in the dialog boxes for parameterization.
Prerequisite
3 Parameterizing the Board
01.99
05.00