A
A.1
Parameter list
A-826
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1244
Characteristic type, torque/power reduction (ARM SRM)
Characteristic type, force/power reduction (SLM)
Min
Standard
Max
Unit
Data type
Effective
1
1
2
–
Unsigned16
immed.
... defines whether reduction is realized with a negative or a positive characteristic.
1
Negative characteristic
2
Positive characteristic
Note: refer to the index entry ”Torque/power reduction”
1245
Threshold, speeddependent M_set smoothing (ARM SRM)
Threshold, velocity-dependent F_set smoothing (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
100000.0
m/min
Floating Point
immed. (SLM)
0.0
0.0
100000.0
rpm
Floating Point
immed. (SRM ARM)
Note:
... is described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1246
Hysteresis, speeddependent M_set smoothing (ARM SRM)
Hysteresis, velocity-dependent F_set smoothing (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
3.0
1000.0
m/min
Floating Point
immed. (SLM)
0.0
50.0
1000.0
rpm
Floating Point
immed. (SRM ARM)
Note:
... is described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1247
Speed threshold, motor changeover 1/2 (ARM)
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
100.0
100000.0
100000.0
rpm
Floating Point
immed. (ARM)
... the speed threshold for the motor changeover is defined with speed threshold (P1013 = 3) to
change over the motor data sets P1xxx to P2xxx.
Note: refer to the index entry ”Motor changeover”
1248
Speed threshold, motor changeover 3/4 (ARM)
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
100.0
100000.0
100000.0
rpm
Floating Point
immed. (ARM)
... the speed threshold for the motor changeover is defined with the speed threshold (P1013 =
3) to change over the motor data sets P3xxx to P4xxx.
Note: refer to the index entry ”Motor changeover”
A Lists
01.99
! 611ue diff !