SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Prerequisites:
”Open–loop torque controlled operation” input signal = 1 signal
P0607 = 1
Torque setpoint via terminal 56.x/14.x
P0612= 2
Setpoint for M
red
via terminal 24.x/20.x
P1241:8
M
red
analog
(refer to
Chapter 6.1.2)
P0620
M
set
analog
(refer to Chapter
6.1.2)
P0619
P1242:8
+
Offset
torque
setpoint
Scaling
torque
setpoint
P1243:8
Scaling
torque/
power
reduction
Character–
P0609
P0614
P0610
P0615
Smoothing
time
PT
1
filter
+
+
Inver-
sion
Inver-
sion
P0608
P0613
A
D
A
D
10 V
Smoothing
time
PT
1
filter
T. 56.x
T. 14.x
T. 24.x
T. 20.x
10 V
P1244
istic
X
P1230
P1235
Offset
correction
Offset
correction
Fig. 6-56 Open–loop torque controlled operation via terminal 56.x/14.x and torque/power reduction via
terminal 24.x/20.x
Reader’s note
The torque/power reduction via terminal 24.x/20.x is described in
Chapter 6.6.4.
M
set
mode via
term. 56.x/14.x
and
M
red
mode via
term. 24.x/20.x
6 Description of the Functions