4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-171
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
!
Danger
The circuits of Temp–F and Temp–S neither have ”protective
separation” between each other nor to the power circuits in
accordance with VDE 0160/EN 50178.
This is the reason that they may not be considered as SELV/PELV
circuit nor may they be connected with such circuits. Also refer to
Reference:
/PJLM/ Configuration Manual
1FN1, 1FN3 Linear Motors
Section ”General information on the connection
system (CON)”
– Temperature sensor evaluation (refer to Chapter 4.10.5)
Reader’s note
Section ”General information on the connection system (CON)” in:
Reference:
/PJLM/ Configuration Manual,
1FN1, 1FN3 Linear Motors
5. Measuring system cable
Is the measuring system cable inserted at X411/X412 or at the
adapter connector of the temperature sensor coupling cable?
!
Danger
Presently, the connection does not correspond to ”protective
separation” according to VDE 0160/EN 50178.
This is the reason that they may not be considered as SELV/PELV
circuit nor may they be connected with such circuits. Also refer to
Reference:
/PJLM/ Configuration Manual
1FN1, 1FN3 Linear Motors
Section ”General information on the connection
system (CON)”
4 Commissioning