Parameter list
A-736
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0079
Reformat memory
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
immed.
... the memory can be reformated for the traversing blocks, i.e. re-segmented.
0
inactive, initial status
0 –> 1
Re-format memory is initiated
Advantages of a re-formatted memory:
When displaying the blocks via SimoCom U or via the display unit on the front panel, the blocks
are located at the beginning of the memory, are sorted according to increasing block numbers,
and there are no gaps.
Note:
The parameter is automatically reset to 0 when reformating has been completed.
0080:64 Block number
Min
Standard
Max
Unit
Data type
Effective
–1
–1
63
–
Integer16
PrgE
A traversing block must be assigned a valid block number, so that it can be started.
–1
invalid block number
0 to 63
valid block number
The block change enable itself is saved in the traversing block in P0087:64 (mode block change
enable).
Several blocks (e. g. for blocks with the block step enable CONTINUE FLYING) are processed
in the increasing sequence of the block numbers.
The block number must be unique over all traversing blocks.
Note: refer to the index entry ”Traversing blocks”
0081:64 Position
Min
Standard
Max
Unit
Data type
Effective
–200000000
0
200000000
MSR
Integer32
PrgE
... specifies the target position in the traversing block.
The target position is approached dependent on P0087:64 (mode positioning mode).
Note: refer to the index entry ”Traversing blocks”
0082:64 Velocity
Min
Standard
Max
Unit
Data type
Effective
1000
600000
2000000000
c*MSR/min
Unsigned32
PrgE
... defines the velocity, with which the target position is approached.
Note: refer to the index entry ”Traversing blocks”
0083:64 Acceleration override
Min
Standard
Max
Unit
Data type
Effective
1
100
100
%
Unsigned16
PrgE
... specifies which override has an effect on the maximum acceleration (P0103).
Note: refer to the index entry ”Traversing blocks”
0084:64 Deceleration override
Min
Standard
Max
Unit
Data type
Effective
1
100
100
%
Unsigned16
PrgE
... specifies which override has an effect on the maximum deceleration (P0104).
Note: refer to the index entry ”Traversing blocks”