6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-413
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-38
Parameters used to program traversing blocks, continued
No.
Effective
Units
Max.
Standard
Min.
Name
0082:64
Velocity
1 000
600 000
2 000 000 000
c*MSR/min
PrgE
... defines the velocity with which the target position is approached.
v
t
a
P0103
P0104
P0082:x
Programmed
velocity
Maximum
acceleration
Maximum
deceleration
v
a
Velocity and acceleration profile for ”long” or ”short” blocks
t
t
t
Note:
x: Space retainer in the block memory
If the programmed velocity in P0082:64 is greater than in P0102 (maximum velocity), then
the axis is limited to the maximum velocity and warning 803 is issued (programmed veloc-
ity > maximum velocity).
For short traversing distances, it is possible that the programmed velocity will not be
reached.
0083:64
Acceleration
override
1
100
100
%
PrgE
... specifies which override is effective at the maximum acceleration (P0103).
a
act
= P0103
P0083:x
100 %
x: Space retainer in the block memory
0084:64
Deceleration
override
1
100
100
%
PrgE
... specifies which override is effective at the maximum deceleration (P0104).
a
brake, act
= P0104
P0084:x
100 %
x: Space retainer in the block memory
6 Description of the Functions
01.99
! not 611ue !