The following parameters should be set at the slave drive:
Source for the ”external position reference value”
––> e.g. P0891 = 4: PROFIBUS–DP
Select the coupling type using P0410
––>
e.g. P0410 = 7: Coupling to the absolute po P0412
via the digital input signal
Define the optional coupling factor for revolutions, master and slave
drive
––> P0401 and P0402 (e.g. 1)
Fig. 5-40 Parameterizing the couplings
The DP master must set control word PosStw.4 in order to activate the
coupling.
Configuring the
coupling
5 Communications via PROFIBUS DP