A
A.1
Parameter list
A-795
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0986:2
Number list_7
(–> 6.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
All of the parameter numbers defined in the drive are saved in parameters 980 – 989 from sub-
index 1. The arrays are assigned consecutively without any gaps. If a sub-index contains a
zero, then this is the end of the list of defined parameters. If a sub-index contains the parameter
number of the next list parameter, then the list continues there.
Note:
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
0987:2
Number list_8
(–> 6.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
All of the parameter numbers defined in the drive are saved in parameters 980 – 989 from sub-
index 1. The arrays are assigned consecutively without any gaps. If a sub-index contains a
zero, then this is the end of the list of defined parameters. If a sub-index contains the parameter
number of the next list parameter, then the list continues there.
Note:
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
0988:2
Number list_9
(–> 6.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
All of the parameter numbers defined in the drive are saved in parameters 980 – 989 from sub-
index 1. The arrays are assigned consecutively without any gaps. If a sub-index contains a
zero, then this is the end of the list of defined parameters. If a sub-index contains the parameter
number of the next list parameter, then the list continues there.
Note:
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
0989:2
Number list_10
(–> 6.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
All of the parameter numbers defined in the drive are saved in parameters 980 – 989 from sub-
index 1. The arrays are assigned consecutively without any gaps. If a sub-index contains a
zero, then this is the end of the list of defined parameters. If a sub-index contains the parameter
number of the next list parameter, then the list continues there.
Note:
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
1000
Current controller cycle
Min
Standard
Max
Unit
Data type
Effective
2
4
4
31.25
µ
s
Unsigned16
PO
Current controller clock cycle = P1000 x 31.25 microseconds
Note:
refer to the index entry ”Clock cycles”
A Lists
01.99
! 611ue diff !
04.05