769
Denominator bandwidth > twice the natural frequency
Cause
The denominator bandwidth of a current or speed setpoint filter is
greater than twice the natural frequency.
This alarm is only generated for the general bandstop, if the following is
valid:
Speed setpoint filter 1: P1516 > 2 * P1514 or P1520 <> 100.0
Speed setpoint filter 2: P1519 > 0.0 or P1521 <> 100.0
Current setpoint filter 1: P1212 > 0.0
Current setpoint filter 2: P1215 > 0.0
Current setpoint filter 3: P1218 > 0.0
Current setpoint filter 4: P1221 > 0.0
Remedy
The denominator bandwidth of a current or speed setpoint filter must
be less than twice the natural frequency.
Speed setpoint filter 1: P1515 <= 2 * P1514 * 0.01 * P1520
Speed setpoint filter 2: P1518 <= 2 * P1517 * 0.01 * P1521
Current setpoint filter 1: P1211 <= 2 * P1210
Current setpoint filter 2: P1214 <= 2 * P1213
Current setpoint filter 3: P1217 <= 2 * P1216
Current setpoint filter 4: P1220 <= 2 * P1219
Acknowledgement RESET FAULT MEMORY
Stop response
STOP II (SRM, SLM) STOP I (ARM)
770
Format error
Cause
The calculated bandstop filter coefficients cannot be represented in the
internal format.
Remedy
Change filter setting.
Acknowledgement RESET FAULT MEMORY
Stop response
STOP II (SRM, SLM) STOP I (ARM)
771
Induction motor oper.: drive converter frequency
motor \%d not permissible
Cause
In induction motor operation (selected by P1465 < P1146), drive con-
verter frequencies of 4 or 8 kHz are permissible.
Remedy
– Change P1100
– Cancel induction motor operation (P1465 > P1146)
Acknowledgement RESET FAULT MEMORY
Stop response
STOP II (SRM, SLM) STOP I (ARM)
772
Induction motor oper.: speed controller gain, motor
\%d too high
Cause
The P gain of the speed controller (P1451) is too high.
Remedy
For the speed controller, enter a lower value for the P gain (P1451).
Acknowledgement RESET FAULT MEMORY
Stop response
STOP II (SRM, SLM) STOP I (ARM)
7 Fault Handling/Diagnostics