Basic functions of the cyclic data transfer
5-207
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The PPO selection can be subdivided into:
Net data without parameter area
with 2 to 16 words for the process data.
and
Net data with parameter area
with 2 to 16 words for the process data.
These are the PPO types 1, 2 and 5.
A different number of process data is permissible for the setpoints and
actual values (from SW 3.1).
In addition to be able to freely set the number of process data, the con-
figuring allows standard settings to be selected. This includes, in addi-
tion to the PPO types PPO1 to PPO5 (refer to Table 5-1) a whole se-
ries of configured functions (GSD file, Drive ES), which are suitable for
the various standard telegrams.
Table 5-1
Parameter process data objects (PPO types)
Net data
PKW
Refer to Chapter
5.6.7
PZD
In closed–loop speed controlled operation, refer to Chapter 5.6.6
In the positioning mode, refer to Chapter 5.6.6
PKE
IND
PWE
PZD
1
PZD
2
PZD
3
PZD
4
PZD
5
PZD
6
PZD
7
PZD
8
PZD
9
PZD
10
1st
word
2nd
word
3rd
word
4th
word
1st
word
2nd
word
3rd
word
4th
word
5th
word
6th
word
7th
word
8th
word
9th
word
10th
word
PPO1
PPO2
PPO3
PPO4
PPO5
Abbreviations:
PPO
Parameter Process data Object
PKW
Parameter ID value
PKE Parameter
ID
IND
Sub–index,
sub–parameter number, array index
PWE
Parameter value
PZD
Process data
Notice
The five various PPOs are selected with different data length
depending on the task that the drive has to fulfill in the automation
environment.
The process data structure of the telegram can be defined and configu-
red as follows from SW 3.1:
By selecting a standard telegram
By freely configuring a telegram
––> Refer to Chapter 5.6.5
PPOs
Configuring
process data
(from SW 3.1)
5 Communications via PROFIBUS DP