6
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6-409
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-36
Overview of the traversing blocks, continued
Block
memory...
Memory
Description
Description
Mode
Spindle posi-
tioning (from
SW 5.1)
Block change enable
Positioning
mode
IDs
87:0
87:1
...
Xxxx
Target position
via
0: Traversing
block running
1: PROFIBUS
xXxx
0: END (standard)
1: CONTINUE WITH
STOP
2: CONTINUE FLYING
3: CONTINUE EXTER-
NAL
xxXx
0: ABSOLUTE
(standard)
1: RELATIVE
2: ABS_POS
3: ABS_NEG
xxxX
1:
SKIP_
BLOCK
...
87:63
6 Description of the Functions
01.99
! not 611ue !
02.02