A
A.1
Parameter list
A-766
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0660
Function of input terminal I0.x
Min
Standard
Max
Unit
Data type
Effective
0
35
86
–
Unsigned16
immed. (ARM)
0
0
86
–
Unsigned16
immed. (SRM SLM)
... defines the function of input terminal I0.x on the control module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I0.x to I3.x” or ”List of the input signals”
0661
Function of input terminal I1.x
Min
Standard
Max
Unit
Data type
Effective
0
7
86
–
Unsigned16
immed. (ARM)
0
0
86
–
Unsigned16
immed. (SRM SLM)
... defines the function of input terminal I1.x on the control module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I0.x to I3.x” or ”List of the input signals”
0662
Function of input terminal I2.x
Min
Standard
Max
Unit
Data type
Effective
0
3
86
–
Unsigned16
immed.
... defines the function of input terminal I2.x on the control module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I0.x to I3.x” or ”List of the input signals”
0663
Function of input terminal I3.x
Min
Standard
Max
Unit
Data type
Effective
0
4
86
–
Unsigned16
immed.
... defines the function of input terminal I3.x on the control module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I0.x to I3.x” or ”List of the input signals”
0664
Function of input terminal I4
Min
Standard
Max
Unit
Data type
Effective
0
60
86
–
Unsigned16
immed.
... defines the function of input terminal I4 on the optional TERMINAL module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I4 to I11” or ”List of the input signals”
0665
Function of input terminal I5
Min
Standard
Max
Unit
Data type
Effective
0
59
86
–
Unsigned16
immed.
... defines the function of input terminal I5 on the optional TERMINAL module.
The function number from the ”List of input signals” is entered.
Note:
refer to the index entry ”Terminals term. I4 to I11” or ”List of the input signals”
A Lists
01.99
! 611ue diff !
04.05