4
01.99
4.10 Linear motors (1FN1, 1FN3 motors)
4-173
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
– ”Measuring system/encoder” dialog box
Field
”Which motor measuring system are you using?” –> Enter data
The encoder data should be entered after ”continue”.
”Linear measuring system” field
Incremental – a zero mark
There is an incremental measuring system with 1 zero mark
in the traversing range.
Incremental – several zero marks
An incremental measuring system is used with several zero
marks in the traversing range.
Incremental – no zero mark
An incremental measuring system is used without any zero
marks in the traversing range.
Absolute (EnDat)
An absolute measuring system (EnDat) is used.
Speed actual value inversion
The inversion must be set, as was already determined under
”Check in the no–current status”.
Grid spacing
The grid spacing should be set as was already entered in the
”check in the no–current status” point.
Rotor position identification
yes
(only for incremental measuring systems)
– ”Operating mode” dialog box
– ”Complete the drive configuration” dialog box
After the data that has been set has been carefully checked, the
drive configuration is completed by pressing
”Accept this drive configuration”.
4 Commissioning