2
2.1
Installing/removing control boards and modules
2-64
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
– Exit SimoCom U.
– Make a back–up copy of the test file ”...\siemens\lists\control.txt”
in the main SimoCom U directory (generally under ”C:\Pro-
grams\Siemens\SimoComU”).
– Then open this file with Microsoft Wordpad (not with a text edi-
tor!).
– Search for the following line under the Section ”611U” or the last
line of this section:
– 6SN1118–1NJ00–0AAx
259
0x00000000 1 1 2 1 ;611U
resolver 1–axis X_SOLL
– Insert the following lines directly below:
– 6SN1118–0NH01–0AA0
5
0x00000000 2 2 1 7 ;611U
encoder HR 2–axis N_SOLL
– 6SN1118–0NK01–0AA0
7
0x00000000 1 2 1 8 ;611U
resolver HR 2–axis N_SOLL
– 6SN1118–0NJ01–0AA0
8
0x00000000 1 1 1 8 ;611U
resolver HR 1–axis N_SOLL
– 6SN1118–1NH01–0AA0
261
0x00000000 2 2 2 7 ;611U
encoder HR 2–axis X_SOLL
– 6SN1118–1NK01–0AA0
263
0x00000000 1 2 2 8 ;611U
resolver HR 2–axis X_SOLL
– 6SN1118–1NJ01–0AA0
264
0x00000000 1 1 2 8 ;611U
resolver HR 1–axis X_SOLL
– As last line, insert under the Section ”611UE”:
– 6SN1118–0NH11–0AA0
9
0x00000000 2 2 1 9 ;611UE
encoder HR 2–axis N_SOLL
– Save the ”control.txt” file.
– Restart SimoCom U and continue with Point 6.
6. Save your machine data from the ”old” memory module
(File: ”*.par”) using the ”SimoCom U” start–up tool.
7. Again remove the ”new” control board and replace the ”old” memory
module by the ”new” memory module. Software release
SW 5.1
is already installed on the ”new” memory module.
8. Insert the ”new” control board back into the power module and
tighten the retaining screws (2 screws at the front panel, torque =
0.8 Nm).
9. Re–connect the front panel of the module corresponding to the con-
nection diagram.
Insert the mating connector at the appropriate interface.
2 Installing and Connecting-Up
01.99
08.02
02.02