5
5.6
Net data (PKW and PZD area)
5-278
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
PROFIBUS–DP
SIMATIC S7–300 (CPU: S7–315–2–DP)
MPI
Output signals
at the DP slave
Input signals
at the DP slave
PKW area (task)
PAW 272 = 0110 0001 1101 1001
PAW 274 = 0000 0000 0000 0001
PAW 276 = 0000 0000 0000 0000
PAW 278 = 0000 0000 0000 0000
IND
PKE
PWE1
PWE2
AK = 6, PNU = 945
Index = 1
Value (high)
Value (low)
PKW area (response)
PEW 272 = 0101 0001 1101 1001
PEW 274 = 0000 0000 0000 0001
PEW 276 = 0000 0000 0000 0000
PEW 278 = 130 (for example)
IND
PKE
PWE1
PWE2
AK = 5, PNU = 945
Index = 1
Value (high)
Value (low)
”DP slave 611U”:
Control board with
”SIMODRIVE 611 universal”
with optional PROFIBUS–DP
module
PAW
Peripheral output word
PEW Peripheral input word
PKE Parameter
ID
IND
Sub–index, sub–parameter number, array index
PWE Parameter value
AK
Task and response ID
PNU
Parameter number
PG/PC
Fig. 5-20 Example: Reading parameters via PROFIBUS
Note
The ”FC 92” SIMATIC S7 block can be used for ”read parameters via
PROFIBUS”.
This block is included in the toolbox of the CD for ”SIMODRIVE 611
universal” in the file ”s7_Baust.arj” and is documented using its block
comments.
There are additional application examples in the toolbox with the
”read/write parameter” function
(e.g. interface 611u <––> S7 in the file ”611u39.arj”).