Parameter list
A-805
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1032
DM single-turn resolution, absolute value encoder
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
0
4294967295
–
Unsigned32
PO
Resolution of the absolute value encoder in measuring pulses per revolution.
Note:
DM ––> Direct measuring system
Single-turn resolution for indirect measuring system (IM, motor encoder) ––> refer to P1022
1033
DM diagnostics
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
Bit 0
Light source failed
Bit 1
Signal amplitude too low
Bit 2
Code connection erroneous
Bit 3
Overvoltage
Bit 4
Undervoltage
Bit 5
Overcurrent
Bit 6
Battery must be changed
Bit 7
Control check error
Bit 8
EnDat encoder cannot be used
Bit 9
CD track for ERN1387 encoder erroneous or
EQN encoder connected, or
incorrectly parameterized (not on EQN, P1027.3)
Bit 10 Protocol cannot be exited
Bit 11 No encoder connected, or
incorrect encoder cable
Bit 12 TIMEOUT for measured value read
Bit 13 CRC error, parity bit
Bit 15 Defective measuring encoder
Note:
DM ––> Direct measuring system
Diagnostics for indirect measuring system (IM, motor encoder) ––> refer to P1023
Bit 7 and 13 = 1 ––> Incremental and absolute track do not match
ERN: incremental encoder system
EQN: absolute encoder system
1034
DM grid spacing
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
20000
4294967295
nm
Unsigned32
PO
Note:
DM ––> Direct measuring system
1036
DM encoder code number
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
0
65535
–
Unsigned16
PO
The encoder number defines the connected measuring system.
Note:
DM ––> Direct measuring system
Encoder code for indirect measuring system (IM, motor encoder) ––> refer to P1006
refer to the index entry ”Encoder code”
A Lists
01.99