A
A.1
Parameter list
A-821
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1201:8
Current setpoint filter type
Min
Standard
Max
Unit
Data type
Effective
0
0
800F
Hex
Unsigned16
immed.
... specifies the type of the 4 current setpoint filters.
Bit 0
Filter 1
= 1
Bandstop (filter parameters: P1210:8, P1211:8, P1212:8)
= 0
Low pass (filter parameters: P1202:8, P1203:8)
Bit 1
Filter 2
= 1
Bandstop (filter parameters: P1213:8, P1214:8, P1215:8)
= 0
Low pass (filter parameters: P1204:8, P1205:8)
Bit 2
Filter 3
= 1
Bandstop (filter parameters: P1216:8, P1217:8, P1218:8)
= 0
Low pass (filter parameters: P1206:8, P1207:8)
Bit 3
Filter 4
= 1
Bandstop (filter parameters: P1219:8, P1220:8, P1221:8)
= 0
Low pass (filter parameters: P1208:8, P1209:8)
Bit 15
Bandstop, transformation type (from SW 3.3)
= 1
Z transformation
= 0
Bilinear transformation (standard)
Note:
Before parameterizing the filter type, the appropriate filter parameters must be assigned.
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1202:8
Natural frequency current setp. filter 1
Min
Standard
Max
Unit
Data type
Effective
0.0
2000.0
8000.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1203:8
Damping, current setp. filter 1
Min
Standard
Max
Unit
Data type
Effective
0.05
0.7
5.0
–
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1204:8
Natural frequency current setp. filter 2
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
8000.0
Hz
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1205:8
Damping, current setp. filter 2
Min
Standard
Max
Unit
Data type
Effective
0.05
1.0
5.0
–
Floating Point
immed.
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2