A
A.1
Parameter list
A-771
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0698
Image of the output terminals
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
The signal statuses of the output terminals are displayed using these parameters.
bit 11 (t. O11), bit 10 (t. O10), bit 9 (t. O9), bit 8 (t. O8),
bit 7 (t. O7), bit 6 (t. O6), bit 5 (t. O5), bit 4 (t. O4),
bit 3 (T. O3.x), bit 2 (T. O2.x), bit 1 (T. O1.x), bit 0 (T. O0.x)
Bit x = ”1” ––> output terminal has signal status ”1”
Bit x = ”0” ––> output terminal has signal status ”0”
Example: P0698 = 0006 ––> Term. O2.x and O1.x have signal status ”1”
Note:
Non-assigned bits are displayed with ”0”.
Terminals O4 to O11 are on the optional TERMINAL module.
0699
Inversion output terminal signals
Min
Standard
Max
Unit
Data type
Effective
0
0
FFF
Hex
Unsigned16
immed.
This parameter is used to define which output terminal signals are to be output inverted.
bit 11 (t. O11), bit 10 (t. O10), bit 9 (t. O9), bit 8 (t. O8),
bit 7 (t. O7), bit 6 (t. O6), bit 5 (t. O5), bit 4 (t. O4),
bit 3 (T. O3.x), bit 2 (T. O2.x), bit 1 (T. O1.x), bit 0 (T. O0.x)
Bit x = ”1” ––> output terminal is inverted
Bit x = ”0” ––> output terminal is not inverted
Example: P0699 = 0003 ––> Term. O1.x and O0.x are output inverted
Note:
Non-assigned bits are displayed with ”0”.
Terminals O4 to O11 are on the optional TERMINAL module.
0700
Operating mode
Min
Standard
Max
Unit
Data type
Effective
0
1
3
–
Unsigned16
PO
0
Drive inactive (only drive B)
This means a double-axis module can only be operated with a single axis.
Should there be no communication with the inactive drive B via PROFIBUS?
If yes, then communication must be disabled with P0875=0.
1
Speed/torque setpoint
The drive can be operated as follows in this operating mode:
– Closed-loop speed controlled operation (n-set operation)
– Open-loop torque controlled mode
(M setpoint operation)
– Torque reduction (M reduction)
Note:
Operation is possible via terminals, via PROFIBUS-DP or both together.
2
External position reference value (from SW 3.3)
No longer available from SW 4.1. Select ”Positioning” mode.
3
Positioning (from SW 2.1)
The drive can be operated as follows in this operating mode:
– Programming, selecting and starting traversing blocks
– Enter velocity override
– Torque reduction (M reduction)
Note:
Operation is possible via terminals, via PROFIBUS-DP or both together.
A Lists
01.99
! 611ue diff !
04.05