A
A.1
Parameter list
A-836
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1503:8
Time constant, speed setpoint filter 2 (ARM SRM)
Time constant, velocity setpoint filter 2 (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.0
0.0
500.0
ms
Floating Point
immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1506:8
Natural frequency, speed setpoint filter 1 (ARM SRM)
Natural frequency, velocity setpoint filter 1 (SLM)
Min
Standard
Max
Unit
Data type
Effective
10.0
2000.0
8000.0
Hz
Floating Point
immed.
Note:
The filter can be switched out/switched in via the ”First speed setpoint filter off” input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1507:8
Damping, speed setpoint filter 1 (ARM SRM)
Damping, velocity setpoint filter 1 (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.2
0.7
5.0
–
Floating Point
immed.
Note:
The filter can be switched out/switched in via the ”First speed setpoint filter off” input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1508:8
Natural frequency, speed setpoint filter 2 (ARM SRM)
Natural frequency, velocity setpoint filter 2 (SLM)
Min
Standard
Max
Unit
Data type
Effective
10.0
2000.0
8000.0
Hz
Floating Point
immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1509:8
Damping, speed setpoint filter 2 (ARM SRM)
Damping, velocity setpoint filter 2 (SLM)
Min
Standard
Max
Unit
Data type
Effective
0.2
0.7
5.0
–
Floating Point
immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1514:8
Blocking frequency, speed setpoint filter 1 (ARM SRM)
Blocking frequency, velocity setpoint filter 1 (SLM)
Min
Standard
Max
Unit
Data type
Effective
1.0
3500.0
7999.0
Hz
Floating Point
immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
A Lists
01.99
! 611ue diff !