Parameterizing using the parameterizing and start–up tool SimoCom U
3-99
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The information listed in Table 3-3 provides basic information and in-
structions on how to handle the SimoCom U parameterizing and start–
up tool.
Table 3-3
Information on SimoCom U
Function
Description
Tasks,
which can be exe-
cuted using
SimoCom U
Check the wiring (go into the Online Help: connection diagrams)
Establish a connection to the drive to be parameterized
Change the parameters
–
The essential parameters are changed in interactive dialog
–
All of the parameters can be changed using the list parameterization
Upgrade firmware
Optimize the controller parameters
Traverse the axis
Diagnose the drive status
–
Obtain an overview of all of the connected drives and their status
–
Identify the connected hardware
–
Obtain a display of the terminal status
–
Obtain a display of the alarms and information on how they can be
removed
Carry–out diagnostics
–
Parameterize the test sockets (DAU1, DAU2)
This means that selected signals in the drive can be routed to the test
sockets for measurement with an oscilloscope.
–
Execute the measuring function
It is possible to measure the most important quantities in the closed–
loop current and speed control loop in the time and frequency domains
without having to use external measuring equipment; these can then
also be graphically displayed.
–
Execute the trace function
Selected measuring quantities in the drive can be measured correspond-
ing to the specified measuring parameters, and graphically displayed
using SimoCom U.
Simulate terminal signals
Save the results
–
Save the parameters in the drive FEPROM
–
Save the parameters in a file/open a file
–
Print the parameters
Comparing parameter sets (from version 02.04)
This allows the differences between 2 parameter sets to be identified.
Boot the board (from version 03.03)
The board status when originally shipped can be re–established using this
function.
User–parameter list (from version 03.03)
The user can include a parameter in this list. This list has the same function-
ality as the expert list.
Password protection (from version 08.01)
Using this function, access protection can be provided for SimoCom U and
the drive firmware so that the drive configuration cannot be changed.
To set the password protection, refer to Chapter 4.3.3.
Information on
SimoCom U
3 Parameterizing the Board