6
6.15 Spindle positioning (from SW 5.1)
6-612
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following signals are used for the ”spindle positioning” function:
Input signals
(refer under the index entry ”Input signal, digital – ...)
– Input signal, ”spindle positioning on”
––> using an input terminal with function number 28
––> using the PROFIBUS control signal ”STW1.15”
– Input of traversing blocks
––> via an input terminal, or
––> via PROFIBUS–DP
When the traversing block selection is changed (number), the
position is immediately changed to the position specified in the
traversing block.
Output signals
(refer under the index entry, ”output signal, digital – ...)
The output signals are only effective when selecting ”spindle posi-
tion on”.
– Output signal, ”spindle positioning on”
––> using an output terminal with function number 28
––> using the PROFIBUS status signal ”ZSW1.15”
– Output signal ”spindle position reached”
––> setting a window with P0134
––> using an output terminal with function number 59
––> using PROFIBUS status signal ”MeldW.15”
– Output signal ”reference position reached/outside reference posi-
tion”
––> setting values with P0320, P0321
––> using an output terminal with function number 60
––> using PROFIBUS status signal ”MeldW.14”
Input/output
signals
(refer to Section
6.4)
6 Description of the Functions
01.99
02.02
! not 611ue !