A
A.1
Parameter list
A-855
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1826
Status test socket 1
Min
Standard
Max
Unit
Data type
Effective
0
1
1
–
Unsigned16
immed.
This parameter defines the status of test socket 1 for this drive.
0
test socket is inactive
1
test socket is active
As always only one drive can output one value at a test socket, when changing the parameter
in one drive, the parameter in the other drive is appropriately changed.
Note:
On a 2-axis module, the test sockets are pre-set as follows after the first start-up:
Drive A: Test socket 1 = active (P1826 = 1) and test socket 2 = inactive (P1836 = 0)
Drive B: Test socket 1 = inactive (P1826 = 0) and test socket 2 = active (P1836 = 1)
(refer to the index entry ”Test sockets”)
1830
Signal number test socket 2
Min
Standard
Max
Unit
Data type
Effective
0
14
530
–
Unsigned16
immed.
Description, refer to that for P1820.
1831
Shift factor test socket 2
Min
Standard
Max
Unit
Data type
Effective
0
12
47
–
Unsigned16
immed.
Description, refer to that for P1821.
1832
Offset test socket 2
Min
Standard
Max
Unit
Data type
Effective
–128
0
127
–
Integer16
immed.
Description, refer to that for P1822.
1833
Segment address test socket 2
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
immed.
Note: Internal Siemens
1834
Offset address test socket 2
Min
Standard
Max
Unit
Data type
Effective
0
0
FFFFFF
Hex
Unsigned32
immed.
Note: Internal Siemens
1836
Status test socket 2
Min
Standard
Max
Unit
Data type
Effective
0
1
1
–
Unsigned16
immed.
Description, refer to that for P1826.
A Lists
01.99
! 611ue diff !
04.05