DOUBLER
DOUBLER
2
2
A Reg. Trademark of TSM - US Patent No. 4,575,004 6,126,141
INSTRUCTIONS FOR INSTALLING
DOUBLER
2
COMPATIBLE WITH ALL 24VAC CONTROLLERS
STEP 1 - INSTALLATION IN THE VALVE BOX
1.
Connect WHITE wire and one wire from each valve
solenoid to your field COMMON wire.
2.
Connect STATION/HOT wire from the controller to BLACK wire
NOTE: Disconnect station/hot from any valves, if applicable.
3.
Connect the RED wire to the FIRST valve solenoid.
4.
Connect the YELLOW wire to the SECOND valve solenoid.
5.
Connect the BLUE wire to the THIRD valve solenoid.
6.
Connect the GRAY wire to the FOURTH valve solenoid.
Be sure to WATERPROOF all wire connections.
CONTROLLER
1 2 3 4 5 6 7 8
C
1
2
DOUBLER
2
3
4
5
6
Specifications
Input: 24VAC, 60Hz Nom. Power: 33ma
Output: 24VAC up to 8A Switch time: 7ms
1 year full replacement warranty against defects
STEP 2 - INSTALLATION AT THE CONTROLLER
1.
Connect jumper wires between the four (4) stations
in the controller you wish to use to control your valves.
(On solid state controllers these stations should not be
in sequence.)
See Example A.
2.
Set your watering times on each of the jumpered stations.
Your valves will operate according to the time set on
these stations.
You have now installed your
DOUBLER
2
.
CONTROLLER
1 2 3 4 5 6 7 8
C
Example A
To
DOUBLER
2
IMPORTANT
: Your
DOUBLER
2
will need to be powered up four times to keep all valves in
sequence. If you are only utilizing three of the
DOUBLER
2
’s outputs, a fourth station with a
minimum time set on it may be used to reset your unit back to its first output. Each time the
DOUBLER
2
receives power it will cycle to the next output in the following order:
Red-Yellow-Blue-Gray, Red-Yellow-Blue-etc.
***If you only need to run two valves on one hot wire, try our o
***If you only need to run two valves on one hot wire, try our o
riginal
riginal
DOUBLER
DOUBLER
***
***
CONTINUED ON REVERSE
IN THE VALVE BOX
AT THE CONTROLLER
AFFIX THIS DECAL IN, ON OR NEAR
CONTROLLER & FILL IN THE STATION
NUMBER(S) YOUR
DOUBLER
2
IS USING.
THIS DECAL WILL PROVIDE FUTURE
REFERENCE FOR USE IN PROGRAMMING
& MAINTENANCE OF THIS SYSTEM.