6
6.6
Analog inputs
6-539
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-54
Parameter for the M
red
mode, continued
Parameters
No.
Effec-
tive
Units
Max.
Stan-
dard
Min.
Description
1244
Characteristic type, torque/power reduction
(SRM, ARM)
Characteristic type, force/power reduction
(SLM)
1
1
2
–
Imme-
diately
... defines whether the reduction is realized with a negative or a positive characteristic.
= 1
Negative characteristic
= 2
Positive characteristic
1259
(from
SW 3.7)
Torque/power reduction mot./gen. (SRM,
ARM)
Force/power reduction mot./gen. (SLM)
0
0
1
–
Imme-
diately
... defines how the torque/power reduction or force/power reduction is effective depending on
the state motoring/regenerating.
=0
Reduction is effective, motoring and generating
= 1
Reduction is only effective motoring
In an emergency situation, the axis can still be quickly braked for P1259 = 1.
6 Description of the Functions
01.99
! not 611ue !