7
7.4
Commissioning functions
7-723
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
7.4.3
Test sockets, DAU1, DAU2
For ”SIMODRIVE 611 universal”, there are two test sockets to output
analog signals, with the following features:
Resolution of the DAU
8 bit
Voltage range
0 V to +5 V
Measurement clock cycle
Speed controller clock cycle
Shift factor (refer to Figs. 7-8 and 7-9)
The resolution is 8 bit. Thus, only an 8 bit section can be output
from a 24/48 bit signal. The shift factor defines how finely the se-
lected signal is quantized.
Module–specific
The test sockets are provided for each module, i.e. they can be acti-
vated and de–activated from each drive.
Only one drive can output one value at a test socket.
Signal selection list
The signals which can be output via the test sockets, can be taken
from the signal selection list for analog outputs (refer to Chap. 6.7).
Note
The test sockets are only provided for test purposes during
commissioning or for service.
Description
7 Fault Handling/Diagnostics
01.99