SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Reader’s note
Additional information about the power modules can be found in
Reference:
/PJU/
SIMODRIVE 611,
Configuration Manual, Drive Converters
Chapter ”Power modules”
This limit protects the power module from continuous overload.
The power module current is limited according to a characteristic if the
drive converter operates for an excessive time above the permissible
load limit. The load limit is set per parameter.
The limit is removed step–by–step if the power module is no longer
being operated above the load limit.
i
max
P1260
i
S6
P1261
i
n
t
10 s
20 s
i
t
4 s
8 s
i
i
2
t limit for the following motors: 1FT6,
1FK6, 1FNx
i
2
t limit for the following motors: 1PHx,
1FE1
Range
without current
limiting
Range
of the limited
current
Range
without current
limiting
Range
of the limited
current
P1261
i
n
i
max
4 min
8 min
Note:
i
max
= P1108 (current limit, power module)
P1099 (limit factor, power module currents)
i
S6
= P1109 (current limit, power module S6)
P1099 (limit factor, power module currents)
i
n
= P1111 (rated current, power module)
P1099 (limit factor, power module currents)
Warning 820
(from SW 3.6)
Warning 820
(from SW 3.6)
Fig. A-2
Behavior when operation is continued at the current limit
i
2
t power module
limiting
(from SW 3.1)