Parameter list
A-790
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0958
Warnings 880–895
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
The parameter displays which warning(s) is(are) present.
Bit 15 (warning 895) ... Bit 0 (warning 880)
Note:
Bit x = 1
Alarm yyy present
Bit x = 0
The alarm assigned to the bit, is not present
refer to the index entry ”PROFIBUS-DP – evaluate warnings”.
0959
Warnings 896–911
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
The parameter displays which warning(s) is(are) present.
Bit 15 (warning 911) ... Bit 0 (warning 896)
Note:
Bit x = 1
Alarm yyy present
Bit x = 0
The alarm assigned to the bit, is not present
refer to the index entry ”PROFIBUS-DP – evaluate warnings”.
0960
Warnings 912–927
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
The parameter displays which warning(s) is(are) present.
Bit 15 (warning 927) ... Bit 0 (warning 912)
Note:
Bit x = 1
Alarm yyy present
Bit x = 0
The alarm assigned to the bit, is not present
refer to the index entry ”PROFIBUS-DP – evaluate warnings”.
0963
Baud rate PROFIBUS
(–> 4.1)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
–
Unsigned16
RO
... contains the actual PROFIBUS baud rate.
0
9.6 kbit/s
1
19.2 kbit/s
2
93.75 kbit/s
3
187.5 kbit/s
4
500 kbit/s
6
1500 kbit/s
7
3000 kbit/s
8
6000 kbit/s
9
12000 kbit/s
10
31.25 kbit/s
11
45.45 kbit/s
A Lists
01.99
! 611ue diff !
04.05