A
A.1
Parameter list
A-854
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1814
Measuring function meas. type
Min
Standard
Max
Unit
Data type
Effective
1
1
8
–
Unsigned16
immed.
Note: refer to the index entry ”Measuring function”
1815
Measuring function meas. period (step change)
Min
Standard
Max
Unit
Data type
Effective
1
100
2000
ms
Unsigned16
immed.
Note: refer to the index entry ”Measurement function”
1816
Measuring function settling time
Min
Standard
Max
Unit
Data type
Effective
0
100
65535
ms
Unsigned16
immed.
Note: refer to the index entry ”Measurement function”
1817
Measuring function no. of averaging ops. (FFT)
Min
Standard
Max
Unit
Data type
Effective
1
16
1000
–
Unsigned16
immed.
Note: refer to the index entry ”Measurement function”
1820
Signal number test socket 1
Min
Standard
Max
Unit
Data type
Effective
0
8
530
–
Unsigned16
immed.
The parameter defines which signal is output via test socket 1.
The signal number from the signal selection list for analog outputs must be entered.
Note: refer to the index entry ”Test sockets”
1821
Shift factor test socket 1
Min
Standard
Max
Unit
Data type
Effective
0
6
47
–
Unsigned16
immed.
... defines the shift factor, with which the analog signal is manipulated.
An 8 bit window of the 24/48 bit signal can be represented via the test socket, thus, the shift
factor must be used to define which window of the internal 24/48 bits is to be displayed.
1822
Offset test socket 1
Min
Standard
Max
Unit
Data type
Effective
–128
0
127
–
Integer16
immed.
The parameter specifies the offset value which is added to the 8-bit output signal.
Note: refer to the index entry ”Test sockets”
1823
Segment address test socket 1
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
immed.
Note: Internal Siemens
1824
Offset address test socket 1
Min
Standard
Max
Unit
Data type
Effective
0
0
FFFFFF
Hex
Unsigned32
immed.
Note: Internal Siemens
A Lists
01.99
! 611ue diff !
04.05