A
A.1
Parameter list
A-851
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1786:5
PKW data received, PROFIBUS
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... is an image of the PKW data received by the DP slave.
The sub-parameter
with index 0 contains the number of valid words
= 0 ––> no PKW data available
= 4 ––> PKW data available
with index 1 of the PKE word (PKE: Parameter identification)
with index 2 of the IND word (IND: Sub-index, sub-parameter number, array index)
with index 3 of the most significant PWE word (PWE: Parameter value)
with index 4 of the least-significant PWE word
Note: refer to the index entry ”PKW area”
1787:5
PKW data sent, PROFIBUS
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... is an image of the PKW data sent to the DP master.
The sub-parameter
with index 0 contains the number of valid words
= 0 ––> no PKW data available
= 4 ––> PKW data available
with index 1 of the PKE word (PKE: Parameter identification)
with index 2 of the IND word (IND: Sub-index, sub-parameter number, array index)
with index 3 of the most significant PWE word (PWE: Parameter value)
with index 4 of the least-significant PWE word
Note: refer to the index entry ”PKW area”
1788:17 Processed data received via PROFIBUS
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... is an image of the process data received by the DP slave (control words).
The sub-parameter
with index 0 contains the number of valid words,
with index 1, the process data 1 (control word 1), with index 2, the process data 2 (PZD2), ...
Note: refer to the index entry ”Process data”
1789:17 Process data sent via PROFIBUS
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
... is an image of the process data sent to the DP master (status words).
The sub-parameter
with index 0 contains the number of valid words,
with index 1, process data 1 (status word 1), with index 2, process data 2 (PZD2), ...
Note: refer to the index entry ”Process data”
A Lists
01.99
! 611ue diff !
04.05