5
5.6
Net data (PKW and PZD area)
5-258
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 5-25
Parameters for configuring the process data, continued
No.
Effective
Units
Max.
Standard
Min.
Name
0916:17
PZD actual value assignment,
PROFIBUS
0
0
65 535
–
Immedi-
ately
... is used to assign the signals to the process data in the actual value telegram.
Permissible signals for the actual value direction (status words) are:
ID
Significance
Abbrev.
Length
Mode
Signals according to the PROFIdrive Profile
50000 / 0
No signal
NIL
16 bit
50002
Status word 1
ZSW1
16 bit
50004
Status word 2
ZSW2
16 bit
50006
Speed actual value A (nist–h)
NIST_A
16 bit
50008
Speed actual value B (n–ist (h + l))
NIST_B
32 bit
50010
Encoder 1 status word
G1_ZSW
16 bit
n–set
50011
Encoder 1 position actual value 1
G1_XIST1
32 bit
n–set
50012
Encoder 1 position actual value 2
G1_XIST2
32 bit
n–set
50014
Encoder 2, status word (from SW 3.3)
G2_ZSW
16 bit
n–set
50015
Encoder 2, pos. act. value 1 (from SW 3.3)
G2_XIST1
32 bit
n–set
50016
Encoder 2, pos. act. value 2 (from SW 3.3)
G2_XIST2
32 bit
n–set
50018
Encoder 3 status word
G3_ZSW
16 bit
n–set
50019
Encoder 3 position actual value 1
G3_XIST1
32 bit
n–set
50020
Encoder 3 position actual value 2
G3_XIST2
32 bit
n–set
Equipment–specific signals, especially for ”SIMODRIVE 611 universal”
50102
Message word
MeldW
16 bit
50104
Analog input, terminals 56.x/14
ADU1
16 bit
50106
Analog input, terminal 24.x/20
ADU2
16 bit
50108
Digital inputs, terminals I0. to I3.x
DIG_IN
16 bit
50110
Utilization
Ausl
16 bit
50112
Active power
Pwirk
16 bit
50114
Smoothed torque setpoint
Msoll
16 bit
50116
Smoothed, torque–generating current Iq
IqGl
16 bit
50118
Ctrl word slave–to–slave traffic (from SW 4.1)
QZsw
16 bit
pos
50119
DC link voltage (from SW 8.3)
UZK1
16 bit
50202
Currently selected block
AktSatz
16 bit
50204
Positioning status word
PosZsw
16 bit
pos
50206
Position actual value (positioning mode)
XistP
32 bit
pos
50208
Position reference value (from SW 4.1)
XsollP
32 bit
pos
50210
Correction, pos. ref. value (from SW 4.1)
Xcor
32 bit
pos
5 Communications via PROFIBUS DP
08.99
04.05