6
6.4
Input/output terminals of the control board
6-525
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-49
List of output signals, continued
Operating
mode
Signal name, description
PROFIBUS bit
pos
n–set
Fct. No.
Angular incremental encoder handwheel active
(from SW 8.1)
84
–
x
AktSatz.13
The output signal indicates whether the angular incremental encoder handwheel function is operational.
1 signal
The angular incremental encoder handwheel function is active.
0 signal
The angular incremental encoder handwheel function is not active.
Angular incremental encoder handwheel evaluation,
bit 0 (from SW 8.1)
85
–
x
AktSatz.11
Angular incremental encoder handwheel evaluation,
bit 1 (from SW 8.1)
86
–
x
AktSatz.12
These 2 status signals can be used to define which angular incremental encoder handwheel evaluation
is selected via parameter P0900.
Ang. incr. enc. hdw. eval.
0
1
2
3
(corresponding to P0900[4])
Bit 0
0
1
0
1
Bit 1
0
0
1
1
Note:
The ”angular incremental encoder handwheel evaluation” function is described in Chapter 6.8.
6 Description of the Functions
01.99
! 611ue diff !
08.01
06.04