background image

Template  40941_J  04-02-10

56281/56282/56283_97_A  02-01-13

1

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.   All material copyright of Balboa Water Group.

BP600 Tech Sheet

Balboa Water Group

System Part Numbers: 

56281 

3kW 800 Incoloy Heater Element

 

 

56282 

3kW 825 Incoloy Heater Element

 

 

56283 

3kW Titanium Heater Element

CE System Model: 

BP16-BP600-RCA-3.0KW

Software ID:   

M100_205 V6

Software Version:   

6.0

Hex File: 

 

BP1600_6.0_BP16TP4.hex

Confi guration Signature:  EDD8C3A4

Eng. Project:   

3833

Base PCBs / PCBA’s: 

Power Board:  22117_B  /  56284 

Logic Board:   22121_E  /  56131-02

Control Panels:

TP600CE  

50014-01

TP600 (non-CE) should not be used 

Software Version 

2.3 and later

TP400T  

50260

Software Version 

2.4 and later

TP400W  

50259

Software Version 

2.4 and later

Auxiliary Panels

AX10A2  

55919

User Interface and Programming Guide:

http://service.balboa-instruments.com/zz40940_download.zip

Summary of Contents for BP600

Page 1: ...3kW 800 Incoloy Heater Element 56282 3kW 825 Incoloy Heater Element 56283 3kW Titanium Heater Element CE System Model BP16 BP600 RCA 3 0KW Software ID M100_205 V6 Software Version 6 0 Hex File BP1600_...

Page 2: ...s hot hot optional neutral ground H 240VAC 60Hz 32A Class A GFCI protected service Circuit Breaker 40A max 4 wires hot hot neutral ground F 120VAC 60Hz 16A Class A GFCI protected service Circuit Break...

Page 3: ...BLOCK TB1 27 30 IN LBS 31 1 34 5 kg cm USE COPPER CONDUCTORS ONLY EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE L2 L1 N F3 10A 250V F2 3A 250V T 150mA 250V F6 J44 J48 J1 J2 J24 J45 J49 J15 J16 J47 J1...

Page 4: ...IMUM OF 90 C TORQUE RANGE FOR MAIN TERMINAL BLOCK TB1 27 30 IN LBS 31 1 34 5 kg cm USE COPPER CONDUCTORS ONLY EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE L2 L1 N F3 10A 250V F2 3A 250V T 150mA 250V...

Page 5: ...the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS02CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TOR...

Page 6: ...on Add 1 High Speed Pump with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS02CE FOR SUP...

Page 7: ...nal Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS03CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TORQUE RANGE...

Page 8: ...with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS03CE FOR SUPPLY CONNECTIONS USE COND...

Page 9: ...d Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS04CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY...

Page 10: ...Not Used non circ Circ Pump Enabled J2 J32 Hot Output Useable Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS04CE FOR SUPPLY C...

Page 11: ...lt J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS05CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C TORQUE RANGE FOR MAIN TERMINA...

Page 12: ...ot Output Useable Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C...

Page 13: ...s from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED WS06CE FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 9...

Page 14: ...on Add 1 High Speed Pump with Heat DIP Switch 2 OFF DIP Switch 2 ON Blue indicates changes from the original Setup 1 default J15 SPA LIGHT BELEUCHTUNG ECLAIRAGE BAIN HYDRO 10VAC 25A LED FOR SUPPLY CON...

Page 15: ...will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Read and understand these instructions before beginning this process Know the Setup Number you want before you power up the spa and...

Page 16: ...nually exit Priming Mode Immediately after exiting Priming Mode press this sequence of buttons Warm Light Warm Warm Warm Warm Continue to press Warm until the diplay shows the Setup Number S 01 S 02 e...

Page 17: ...wer and heater runs on service line L1 with L2 acting as the return 230VAC Set the DIP switches according to the wiring diagram so that total system current draw never exceeds the rated service input...

Page 18: ...s etc Requires a single speed P1 Cleanup Cycle 30 Minutes Between 30 and 240 minutes 30 Minutes or OFF Cleaup as Preference setting Yes Yes No N A Ozone With Heater Pump Always Filters Cleanup Only N...

Page 19: ...Default Temp 70 F Between 50 and 99 F 1 F Freeze Threshold 44 F Between 39 and 54 F 1 F Temp Lock Type Temp Settings Temp Temp Settings N A Time Features Feature Default Options Increment Time Format...

Page 20: ...number of pumps selected is reached No Limitation does not restrict pump or blower operation DIP Switch 5 is used to choose Special Amperage Rule 1 or 2 Drain Mode Disabled Disabled Enabled N A Demo M...

Page 21: ...s 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option 2 Option 3 Option 4 EitherLight Configuration Options TP...

Page 22: ...ons Unused Heat On Filter Cycle On Lock Jets 1 Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option...

Page 23: ...Down Temp Jets 1 Jets 2 Jets 3 Jets 4 Jets 5 Jets 6 Jets 7 Jets 8 Blower 1 Blower 2 Mister 1 Mister 2 Mister 3 Light 1 Light 2 Light 3 Light 4 Fiber Optic Option 1 Option 2 Option 3 Option 4 EitherLig...

Reviews: