VL260

 Quick Reference Guide

INITIAL START-UP

When  your  Spa  is  first  activated  (Powered  up)  it  will  go  into  Priming  Mode 
indicated by “

Pr

” on the LCD readout. The Priming Mode will last for up to 4 

minutes and then the Spa will run in Standard Mode. The Heater Light will flicker 
when Priming, or when the system is self testing.

 Temperature Adjustment

The last measured temperature is consistently displayed on the LCD.  The water 
temperature display is current only when the pump has been running for at least 
2 minutes.
On panels with a single “Temp” or “Set” button, to display the set temperature, 
press  the  button  once.  To  change  the  set  temperature,  press  the  button  a 
second  time  before  the  display  stops  flashing.  Each  press  of  the  button  will 
continue to either raise or lower the set temperature. If the opposite direction 
is desired, allow the display to revert to the current water temperature. Press 
the button to display the set temperature, and again to make the temperature 
change in the desired direction.
On panels with “Warm” and “Cool” buttons, to display the set temperature, press 
“Warm” or “Cool” ocne. To change the set temperature, press a temperature 
button again before the display stops flashing. Each press of “Warm” or “Cool” 
will adjust the set temperature. After three seconds, the display will stop flashing 
and begin to display the current spa temperature.

 Jets 1

Press “Jets 1” to turn Pump 1 on and off, and to shift between low and high 
speeds (if required). The low-speed will turn off after 4 hours. High-speed will 
turn  off  after  15  minutes.  Low-speed  may  run  automatically  at  times,  during 
which it cannot be deactivated from the panel, but high-speed may be operated.

 Jets 2/Jets 3

Press the corresponding button once to turn the device on or off. The device will 
turn off after 15 minutes. Pump 2 may be two-speed on some systems.
Some systems use this one button to control two devices. The first button press 
will activate once device. Press again to have both devices active. Press again 
to turn off the first device only. Press one more time to turn both devices off.

 Blower

The “Blower” button turns the Blower on/off. The Blower automatically turns off 
after 15 minutes.

   Light

Press the Light button to turn the Spa Light on/off. If left on, the Light automatically 
turns off after 4 hours.

SETTING STANDARD/ECONOMY & SLEEP MODE

 Mode/Prog

Depending on system configuration, mode changing may not be available and 
will be locked in Standard Mode.
Mode is changed by pressing “Temp,” then pressing the “Light” button.
Standard  Mode  maintains  set  temperature. 

St

  will  be  displayed  momentarily 

when you switch into Standard Mode.
Economy Mode heats the spa to set temperature only during filter cycle. 

EC

  will 

display when water temp is not current, and will alternate with water temp when 
the pump is running. The Economy icon will be displayed.
Sleep Mode heats the spa to within 20 °F/10°C of the set temperature only 
during  filter  cycles. 

Sl

    will  display  when  water  temp  is  not  current,  and  will 

alternate with current water temp when the pump is running.

Preset Filter Cycles

The  first  preset  filter  cycle  begins  6  minutes  after  the  spa  is  energised.  The 
second preset filter cycle begins 12 hours later. Filter duration is programmable 
for 2, 4, 6 or 8 hours for continuous filtration (indicated by 

FC

). The default filter 

time is 2 hours for non-circ systems and 4 hours for circ systems. 
Yo program, press “Temp,” then “Jets 1.” Press “Temp” to adjust. Press “Jets 1” 
to exit programming.
For non-circ systems, the circ pump and the ozone generator (if installed) run 
during filtration.
For  24  hour  circulation  systems,  the  circ  pump  and  the  ozone  generator  (if 
installed) run 24 hours. In hot environments, the circ pump may turn off for 30 
minute periods, except during filter cycles.
For non - 24 hour circulation systems, the circ pump and ozone generator (if 
installed) run during filtration (and may also run automatically at other times).
At the beginning of each filter cycle all other equipment will run briefly to purge 
the plumbing.