2
2.2
Connecting–up
2-69
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Note
The cable shield should be connected at both cable ends through
the largest possible surface area.
Recommendation for the end of the conductor:
Remove 5 mm of insulation from the end of the conductor and
attach the specified cable lug using the manual crimping tool.
– Pin–type cable lug from the AMP company
Type A, yellow, DIN cable cross–section range 0.14 –
0.35 mm
2
, max. insulation diameter 2.1 mm, Order No.:
165514–1
– Manual crimping tool from AMP
CERTI–CRIMP, Order No.: 169485–0
2.2.2
Connecting–up and setting the line supply infeed module
Connecting–up the line supply infeed module will not be described in
any more detail in this documentation. The following applies:
Reader’s note
Information on connecting–up the supply infeed modules, technical
data as well as an interface overview are included in:
Reference:
/PJU/
SIMODRIVE 611,
Configuration Manual, Drive Converters
Chapter ”Line supply infeed (NE)”
There is a 6–position switch S1 on the top or front of the line supply
infeed module.
The setting of this switch is not described in any more detail in this
documentation. The following applies:
Reader’s note
Information on setting switch S1 at the line supply infeed module is
included in:
Reference:
/PJU/
SIMODRIVE 611,
Configuration Manual, Drive Converters
Chapter ”Line supply infeed (NE)”
Connecting–up
Setting switch S1
2 Installing and Connecting-Up
01.99
10.99