A
A.1
Parameter list
A-763
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0654
Image, input signals, Part 2
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned32
RO
... is an image of selected input signals (terminal and PROFIBUS signals).
Bit 0
Parameter set changeover, 1st input
Bit 1
Parameter set changeover, 2nd input
Bit 2
Parameter set changeover, 3rd input
Bit 3
First speed setpoint filter out
Bit 4
Ramp-up time zero
Bit 5
Reserved for Siemens (smooth running monitoring)
Bit 6
Integrator inhibit, speed controller
Bit 7
Select parking axis
Bit 8
Suppress fault 608
Bit 9
Motor data set changeover, 1st input
Bit 10 Motor data set changeover, 2nd input
Bit 11 Motor changed-over
Bit 12 Tracking operation
Bit 13 Set reference point
Bit 14 Reference cams
Bit 15 Fixed end stop, sensor
Bit 16 Hardware limit switch, plus
Bit 17 Hardware limit switch, minus
Bit 18 Fixed speed setpoint, 1st input <––> block selection, 1st input
Bit 19 Fixed speed setpoint, 2nd input <––> block selection, 2nd input
Bit 20 Fixed speed setpoint, 3rd input <––> block selection, 3rd input
Bit 21 Fixed speed setpoint, 4th input <––> block selection, 4th input
Bit 22 Block selection, 5th input
Bit 23 Block selection, 6th input
Note:
<––>: Signal in ”speed/torque setpoint” <––> in ”positioning”
0655
Image, input signal Part 3
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned32
RO
... is an image of selected input signals (terminal and PROFIBUS signals).
Bit 0
Activate coupling
Bit 1
Jogging incremental
Bit 2
Activate teach-in
Bit 3
Invert input pulses, angular encoder interface
Bit 11 angular incremental encoder handwheel evaluation, bit 0 (from SW 8.1)
Bit 12 angular incremental encoder handwheel evaluation, bit 1 (from SW 8.1)
Bit 13 activate angular incremental encoder handwheel (from SW 8.1)
Bit 17 Activate MDI (from SW 7.1)
Bit 21 Activate coupling via I0.x
Bit 22 Set position reference value
A Lists
01.99
! 611ue diff !
04.05