Net data (PKW and PZD area)
5-217
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
From the perspective of the DP master, control words are setpoints.
The ”DP slave 611U” provides an image of the received process data
P1788:17 (control words, setpoints) in P1788:17 (received process
data, PROFIBUS).
Table 5-3
Overview of the control words (setpoints)
Control word
Operating
mode
Comment
Abbrevi-
ation
Meaning
Data
type
4)
Signal
number
1)
n–set
pos
STW1
Control word 1
U16
50001
x
–
STW1
Control word 1
U16
50001
–
x
STW2
Control word 2
U16
50003
x
x
NSOLL_A
Speed setpoint, most significant
word (nsoll–h)
I16
50005
x
–
NSOLL_B
Speed setpoint, most significant
and least significant word
(nsoll–(h+l))
I32
50007
x
–
from SW 3.1
G1_STW
Encoder 1, control word
2)
U16
50009
x
–
from SW 3.1
G2_STW
Encoder 2, control word
3)
U16
50013
x
–
from SW 3.3
G3_STW
Encoder 3, control word
2)
U16
50017
x
–
from SW 3.1
XERR
System deviation (DSC)
I32
50025
x
–
from SW 4.1
KPC
Position controller gain factor
(DSC)
U32
50026
x
–
from SW 4.1
MomRed
Torque reduction
U16
50101
x
x
DAU1
Analog output, terminal 75.x/15
I16
50103
x
x
DAU2
Analog output, terminal 16.x/15
I16
50105
x
x
DIG_OUT
Digital outputs, terminals O0.x to
03.x
U16
50107
x
x
from SW 3.1
XSP
Target position for ”spindle posi-
tioning”
I32
50109
x
–
from SW 5.1
DezEing
Distributed inputs
U16
50111
x
x
from SW 4.1
MsollExt
External torque setpoint
I16
50113
x
–
from SW 4.1
QStw
Control word, slave–to–slave com-
munication
U16
50117
–
x
from SW 4.1
SatzAnw
Block selection
U16
50201
x
x
(n–set, from
SW 5.1)
PosStw
Position control word
U16
50203
–
x
Over
Override
U16
50205
–
x
Xext
External position reference value
I32
50207
–
x
from SW 4.1
dXcorExt
Correction, external position refer-
ence value
I32
50209
–
x
from SW 4.1
MDIPos
MDI position
I32
50221
–
x
from SW 7.1
MDIVel
MDI velocity
U32
50223
–
x
from SW 7.1
MDIAcc
MDI acceleration override
U16
50225
–
x
from SW 7.1.
MDIDec
MDI deceleration override
U16
50227
–
x
from SW 7.1
Overview of the
control words
(setpoints)
5 Communications via PROFIBUS DP
08.99
02.03