6
6.8
Angular incremental encoder interface (X461, X462)
6-569
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters must be observed when connecting a hand-
wheel to the angular incremental encoder interface:
P0890
Activates the angular incr. enc./encoder interface
P0899
Enters the angular incremental encoder direction
P0900
Angular incremental encoder handwheel evaluation
P0102
Maximum velocity
P0103
Maximum acceleration
P0104
Maximum deceleration
P0655
Image, input signals, Part 3
P0657
Image, output signals, Part 2
The following signals are used to connect a handwheel to the angular
incremental encoder interface:
Input signals
(refer under index entry ”Input signal, digital – ...”)
– Input signal, ”activate angular incremental encoder handwheel”
(from SW 8.1)
––> using an input terminal with function number 84
––> using the PROFIBUS control signal ”SatzAnw.13”
– Input signal, ”angular incremental encoder handwheel evaluation,
bit 0” (from SW 8.1)
––> using an input terminal with function number 85
––> using the PROFIBUS control signal ”SatzAnw.11”
– Input signal, ”angular incremental encoder handwheel evaluation,
bit 1” (from SW 8.1)
––> using an input terminal with function number 86
––> using the PROFIBUS control signal ”SatzAnw.12”
Output signals
(refer under the index entry, ”Output signal, digital – ...”)
– Output signal, ”angular incremental encoder handwheel active”
(from SW 8.1)
––> using an output terminal with function number 84
––> using the PROFIBUS status signal ”AktSatz.13”
– Output signal, ”angular incremental encoder handwheel evalua-
tion, bit 0” (from SW 8.1)
––> using an output terminal with function number 85
––> using the PROFIBUS status signal ”AktSatz.11”
– Output signal, ”angular incremental encoder handwheel evalua-
tion, bit 1” (from SW 8.1)
––> using an output terminal with function number 86
––> using the PROFIBUS status signal ”AktSatz.12”
Note
Compared to the input of control signals via PROFIBUS–DP, the input
terminal functions No. 84 to 86 have a higher priority.
Parameter
overview
(refer to Chapter
A.1)
Input/output
signals
(refer to Section
6.4)
6 Description of the Functions
01.99
06.04