Net data (PKW and PZD area)
5-272
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Dependent on the PPO type, in the positioning mode, the following pro-
cess data is transferred when using standard telegram 101:
Table 5-27
Process data in the positioning mode
PZD
PZD
1
PZD
2
PZD
3
PZD
4
PZD
5
PZD
6
PZD
7
PZD
8
PZD
9
PZD
10
1st
word
2nd
word
3rd
word
4th
word
5th
word
6th
word
7th
word
8th
word
9th
word
10th
word
Master
Slave
Control words
(setpoints)
STW
1
Satz
Anw
Pos
Stw
STW
2
Over
DAU
1
DAU
2
The control words are described in Chapter 5.6.2.
The status words are described in Chapter 5.6.3.
Master
Slave
Status words
(actual values)
ZSW
1
Akt
Satz
Pos
Zsw
ZSW
2
Meld
W
ADU
1
ADU
2
Ausl
Pwirk
Msoll
PPO1
PPO2
PPO3
PPO4
PPO5
Abbreviations:
PPO
Parameter Process data Object
PZD
Process data
STW1
Control word 1
SatzAnw Block selection
PosStw
Position control word
STW2
Control word 2
Over
Override
DAU1
Analog output, terminal 75.x/15
DAU2
Analog output, terminal 16.x/15
ZSW1
Status word 1
AktSatz
Currently selected block
PosZsw
Positioning status word
ZSW2
Status word 2
MeldW
Message word
ADU1
Analog input, terminal 56.x/14.x
ADU2
Analog input, terminal 24.x/20.x
Ausl
Utilization
Pwirk
Active power
Msoll
Smoothed torque setpoint
Note
Operation is also possible with the PPO types which cannot transfer all
process data (e.g. PPO1 and PPO3).
For the positioning mode with a basic functionality, PPO type 3 is
sufficient (2 control and 2 status words).
Process data in
the positioning
mode
5 Communications via PROFIBUS DP
08.99